WIKA O-10(T) O-10(5) 通用型壓力變送器 用于液壓氣壓泵壓縮機

詳細介紹

 

接口尺寸: M12*1(mm) 加工定制:
防護等級: IP65 測量范圍: 0-6to 0-600bar(kPa)
類型: 陶瓷型壓力變送器 防爆等級:
型號: O-10(T) O-10(5) 測量介質: 液體 氣體
精度等級: 0.5 品牌: WIKA/威卡
輸出信號: 4-20(mA) 電源電壓: 10-30(V)

WIKA O-10(T)  O-10(5)

通用型壓力變送器 用于液壓氣壓泵壓縮機

OEM pressure transmitter for general industrial applications
Models O-10 (T), O-10 (5)



Pressure transmitter model O-10 (T)

 

   Applications
     Hydraulics and pneumatics
     Pumps and compressors
     Machine building
     Building services


   Special features
     Measuring ranges from 0 … 6 to 0 … 600 bar
     Non-linearity 0.5 %
     Standard industrial signals
     Electrical connection: Angular connector form A and C,
         circular connector M12 x 1, Metri-Pack series 150,
         cable outlet 2 m unshielded or shielded
     Many internationally customary process connections

 

   Description


    The model O-10 pressure transmitter has been developed for a wide variety of industrial applications. The large range of process and electrical connections as well as all commonly used pressure ranges and output signals set the model O-10
apart.


    For applications in which water is used as a medium we recommend a 5-fold overpressure safety in combination with a condensation-tight case.

    Due to its specifications, its features and its price, the pressure transmitter is ideally suited to OEM applications, with an annual quantity requirement of more than 1,000 units of each article number. Accordingly, the minimum order quantity is 50 units per article number.

 

    The model O-10 has been designed specifically for the demands of the global market. The pressure transmitter offers international units and the corresponding approvals for the North American and Russian markets.


    It goes without saying that the model O-10 can be delivered with customer-specific labelling (e.g. company logo and model designation).

 

   Versions


   Model O-10 (T)
    Standard version


   Model O-10 (5)
    With 5-fold overpressure limit and condensation-tight case


    For applications with water as a medium we recommend a 5-fold overpressure safety for protection against water hammer
    effects, and a condensation-tight case.

 

   Measuring ranges


   Model O-10 (T)

   

     Output signals


    Model O-10 (T)

   

   Voltage supply


   Power supply
    The power supply depends on the selected output signal.
    4 ... 20 mA:          DC 8 ... 30 V
    DC 0.5 ... 4.5 V:     DC 8 ... 30 V
    DC 0 ... 5 V:         DC 8 ... 30 V
    DC 1 ... 5 V:         DC 8 ... 30 V
    DC 0 ... 10 V:        DC 14 ... 30 V
    DC 0.5 ... 4.5 V (ratiometric): DC 4.5 ... 5 V

    The power supply for the pressure transmitter must be made via an energy-limited electrical circuit in accordance with section 9.4 of UL/EN/IEC 61010-1, or an LPS to UL/EN/IEC 60950-1, or class 2 in accordance with UL1310/UL1585 (NEC or CEC).
    The power supply must be suitable for operation above 2,000 m should the pressure transmitter be used at this altitude.


   Total current consumption
    Current output:
    The total current consumption corresponds to the value of the output signal current (4 ... 20 mA), maximum 25 mA


   Voltage output:
    5 mA


   Reference conditions (per IEC 61298-1)


   Temperature
    15 ... 25 °C


   Atmospheric pressure
    860 ... 1,060 mbar


   Humidity
    45 ... 75 % relative


   Power supply
    Current output:             DC 14 V
    Voltage output:             DC 24 V
    Ratiometric output signal:  DC 5 V


   Nominal position
    Calibrated in vertical mounting position with pressure connection facing downwards.

 

   Time response


   Settling time
    < 2 ms

 

   Accuracy data


   Model O-10 (T)


   Non-linearity (per IEC 61298-2)
    ≤ ±0.5 % of span BFSL
    A different non-linearity applies to some measuring ranges, see "Measuring ranges O-10 (T)".


   Measuring deviation of the zero signal
    ≤ ±0.5 % of span

    A different measuring deviation applies to some measuring ranges, see "Measuring ranges model O-10 (T)".


   Accuracy at reference conditions
    ≤ ±1.2 % of span


   Temperature error at 0 ... 80 °C
    ≤ ±1.5 % of span


   Long-term stability
    ≤ ±0.3 % of span/year


    Model O-10 (5)


   Non-linearity (per IEC 61298-2)
    ≤ ±0.5 % of span BFSL


   Measuring deviation of the zero signal
    ≤ ±1 % of span


   Accuracy at reference conditions
    ≤ ±2.0 % of span


   Temperature error at 0 ... 80 °C
    Mean temperature coefficient of zero point:
    Typical: 0.3 % of span/10 K
    Maximum: 0.6 % of span/10 K

 

    Mean temperature coefficient of span:
    ≤ ±0.1 % of span/10 K


   Long-term drift
    ≤ ±0.8 % of span/year

 

   Operating conditions


   Model O-10 (T)


   Ingress protection (per IEC 60529)
    For ingress protections see "Electrical connections model O-10 (T)"
    The stated ingress protection only applies when plugged in using mating connectors that have the appropriate ingress protection.


   Vibration resistance (per IEC 60068-2-6)
    20 g (20 ... 2,000 Hz, 120 min.)


   Shock resistance (per IEC 60068-2-27)
    40 g (6 ms), mechanical shock


   Service life
    10 million load cycles


   Free fall test
    Resistant to an impact onto concrete from 1 m


   Permissible temperatures
    Medium: -30 ... +100 °C
    Ambient: -30 ... +100 °C
    Storage: -30 ... +100 °C


   Model O-10 (5)


   Ingress protection (per IEC 60529)
    For ingress protections see "Electrical connections model O-10 (5)"
    The stated ingress protection only applies when plugged in using mating connectors that have the appropriate ingress protection.


   Vibration resistance (per IEC 60068-2-6)
    20 g (20 ... 2,000 Hz, 120 min)


   Shock resistance (per IEC 60068-2-27)
    40 g (6 ms), mechanical shock

 

   Service life
    10 million load cycles


   Free fall test
    Resistant to an impact onto concrete from 1 m


   Permissible temperatures
    Medium: -40 ... +100 °C
    Ambient: -25 ... +80 °C
    Storage: -25 ... +80 °C


    Other temperature ranges on request

 

   Process connections

   

   Materials


    Non-wetted parts
     Stainless steel 316L
     PBT GF 30
     Cable material (cable outlet) PVC


    Wetted parts
     Stainless steel 316L
     13-8 PH
     For sealing materials see "Process connections"
     Oil and grease free versions are available on request.

 

   Electrical connections


   Model O-10 (T)
    Available connections

   

   Connection diagrams

   

    Complete instrument

   

    CE conformity


    Pressure equipment directive
    97/23/EC


   EMC directive
    2004/108/EC, EN 61326 emission (group 1, class B) and immunity (industrial application)


   RoHS conformity
    Yes


   Approvals
     cULus, safety (e.g. electr. safety, overpressure, ...), USA, Canada
     GOST-R, import certificate, Russia


   Approvals see website

 

   Accessories and spare parts
    Mating connector

   
    Only use the accessories and spare parts listed above, otherwise it could lead to the loss of theapproval.

 

   Ordering information
    Model / Measuring range / Output signal / Process connection / Electrical connection

 

 

   

 